Alpha-amylase reagent kit, CNPG3 method

Diagnostic Kits

Alpha-Amylase Reagent Kit (LiquiMAX Amylase SLR)

A single liquid reagent for alpha-amylase in serum, using CNPG3 as a direct chromogenic substrate in a one-step kinetic assay at 405 nm.

  • CNPG3 substrate
  • Kinetic, 405 nm
  • Linear to 2000 IU/L
  • Single liquid reagent
  • Factor 3178
  • Store at 2–8 °C

WhatsApp or call +91 98795 94445 or +91 96010 24737

Paras Enterprise · Since 2006 · 500+ clinics and hospitals · Dispatch within 48 working hours · Ships across India and abroad

What the Amylase Reagent Is Used For

Alpha-amylase is measured mainly to diagnose and monitor acute pancreatitis. In this kit, amylase acts directly on the substrate CNPG3, releasing 2-chloro-4-nitrophenol, and the rise in absorbance at 405 nm gives the activity. More than 98% of the substrate is hydrolysed, and no helper enzymes such as glucosidase or glucoamylase are needed. It is a single liquid reagent with a fixed kinetic factor of 3178. Made by Avecon Healthcare for semi-automated and automated analyzers.

  • Diagnosing and monitoring acute pancreatitis
  • Investigating raised amylase from salivary gland or other causes
  • Pancreatic panels, together with lipase

Amylase Reagent Specifications

Brand
Avecon Healthcare (LiquiMAX range)
Method
Direct CNPG3 substrate
Reaction
Kinetic, increasing
Wavelength
405 nm
Temperature
37 °C
Timing
60 s delay + 60 s measuring
Sample volume
25 µl
Reagent volume
1.0 ml
Kinetic factor
3178
Linearity
2000 IU/L
Detection limit
7 IU/L
Specimen
Unhaemolysed serum; not EDTA, oxalate or citrate plasma
Storage
2–8 °C until expiry; do not freeze

Amylase Reagent Catalogue Numbers

Ref. No.Pack sizePresentation
AVAMY-102 × 5 mlSingle liquid reagent
AVAMY-204 × 5 mlSingle liquid reagent
AVAMY-505 × 10 mlSingle liquid reagent

Questions

Amylase Reagent FAQs

What is the amylase test used for?

Mainly to diagnose and monitor acute pancreatitis. Amylase can also rise in kidney failure, salivary gland disease and some other conditions, so labs often add lipase.

Which sample should I use?

Unhaemolysed serum. EDTA, oxalate and citrate inhibit amylase, so these plasmas cannot be used. Serum amylase is reported stable for a week at room temperature and 2 months at 2–8 °C.

Can I compare results with other amylase methods?

Not directly. The insert advises that reference values from other substrates should not be compared with CNPG3 results. Each lab should set its own range.

Which instruments can run it?

The insert states it can be used on any discrete semi-automated or automated analyzer. It is read at 405 nm, with a fixed factor of 3178.

How is the amylase reagent shipped, and how fast?

It is shipped in temperature-controlled packaging and usually dispatched within 48 working hours. We deliver across India and also ship outside India. Bulk discounts are available: ask on WhatsApp for a quote.

Get in Touch

Contact Us

Global Enquiry

Enquiry / Request Quote

For clinics, laboratories, and distributors seeking certified IVF and diagnostic products.

Direct Contact

Head Office

Paras Enterprise

117, Medicine Market, near Paldi Cross Road,
Opp. Shefali Centre, Paldi,
Ahmedabad, Gujarat – 380006
India

Mon–Sat · 9:30 AM – 7:30 PM IST

Contact us