Diagnostic Kits
Alpha-Amylase Reagent Kit (LiquiMAX Amylase SLR)
A single liquid reagent for alpha-amylase in serum, using CNPG3 as a direct chromogenic substrate in a one-step kinetic assay at 405 nm.
- CNPG3 substrate
- Kinetic, 405 nm
- Linear to 2000 IU/L
- Single liquid reagent
- Factor 3178
- Store at 2–8 °C
WhatsApp or call +91 98795 94445 or +91 96010 24737
Paras Enterprise · Since 2006 · 500+ clinics and hospitals · Dispatch within 48 working hours · Ships across India and abroad
What the Amylase Reagent Is Used For
Alpha-amylase is measured mainly to diagnose and monitor acute pancreatitis. In this kit, amylase acts directly on the substrate CNPG3, releasing 2-chloro-4-nitrophenol, and the rise in absorbance at 405 nm gives the activity. More than 98% of the substrate is hydrolysed, and no helper enzymes such as glucosidase or glucoamylase are needed. It is a single liquid reagent with a fixed kinetic factor of 3178. Made by Avecon Healthcare for semi-automated and automated analyzers.
- Diagnosing and monitoring acute pancreatitis
- Investigating raised amylase from salivary gland or other causes
- Pancreatic panels, together with lipase
Amylase Reagent Specifications
- Brand
- Avecon Healthcare (LiquiMAX range)
- Method
- Direct CNPG3 substrate
- Reaction
- Kinetic, increasing
- Wavelength
- 405 nm
- Temperature
- 37 °C
- Timing
- 60 s delay + 60 s measuring
- Sample volume
- 25 µl
- Reagent volume
- 1.0 ml
- Kinetic factor
- 3178
- Linearity
- 2000 IU/L
- Detection limit
- 7 IU/L
- Specimen
- Unhaemolysed serum; not EDTA, oxalate or citrate plasma
- Storage
- 2–8 °C until expiry; do not freeze
Amylase Reagent Catalogue Numbers
| Ref. No. | Pack size | Presentation |
|---|---|---|
| AVAMY-10 | 2 × 5 ml | Single liquid reagent |
| AVAMY-20 | 4 × 5 ml | Single liquid reagent |
| AVAMY-50 | 5 × 10 ml | Single liquid reagent |
Questions
Amylase Reagent FAQs
What is the amylase test used for?
Mainly to diagnose and monitor acute pancreatitis. Amylase can also rise in kidney failure, salivary gland disease and some other conditions, so labs often add lipase.
Which sample should I use?
Unhaemolysed serum. EDTA, oxalate and citrate inhibit amylase, so these plasmas cannot be used. Serum amylase is reported stable for a week at room temperature and 2 months at 2–8 °C.
Can I compare results with other amylase methods?
Not directly. The insert advises that reference values from other substrates should not be compared with CNPG3 results. Each lab should set its own range.
Which instruments can run it?
The insert states it can be used on any discrete semi-automated or automated analyzer. It is read at 405 nm, with a fixed factor of 3178.
How is the amylase reagent shipped, and how fast?
It is shipped in temperature-controlled packaging and usually dispatched within 48 working hours. We deliver across India and also ship outside India. Bulk discounts are available: ask on WhatsApp for a quote.
Used Together With
Get in Touch
Contact Us
Global Enquiry
Enquiry / Request Quote
For clinics, laboratories, and distributors seeking certified IVF and diagnostic products.
Direct Contact
WhatsApp · Tap to chat
Call · Tap to call
Email · Tap to email
Head Office
Paras Enterprise
117, Medicine Market, near Paldi Cross Road,
Opp. Shefali Centre, Paldi,
Ahmedabad, Gujarat – 380006
India
Mon–Sat · 9:30 AM – 7:30 PM IST