Lab Equipment
Fully Automated Chemistry Analyzer: AutoMax 200
A random-access, fully automated clinical chemistry analyser that runs a constant 200 tests per hour with single or double reagents.
- 200 tests/hour
- 80 reagent positions
- 40 sample positions
- 2–30 µL sample
- Open reagent system
- 8 wavelengths
WhatsApp or call +91 98795 94445 or +91 96010 24737
Paras Enterprise · Since 2006 · 500+ clinics and hospitals · Dispatch within 48 working hours · Ships across India and abroad
What the Fully Automated Chemistry Analyzer Is Used For
The AutoMax 200 is a compact, fully automated chemistry analyser made by Avecon Healthcare. It runs end point, fixed time and kinetic tests at a constant 200 tests per hour. Reagents sit in a cooled tray at 2–14 °C around the clock, and the reaction tray holds 44 cuvettes at 37 °C. An on-board washing unit cleans and dries the cuvettes automatically. The reagent system is open, so the lab can use the reagents it prefers. A locked reagent mode is optional.
- Routine biochemistry in hospital and diagnostic labs
- Colorimetric and turbidimetric tests: end point, fixed time and kinetic
- Labs that want to move from a semi-automatic analyser to walk-away testing
- Running open-system reagent kits from different makers
Fully Automated Chemistry Analyzer Specifications
- Make
- Avecon Healthcare
- Model
- AutoMAX-200
- Type
- Fully automated chemistry analyzer, random access
- Reagent system
- Open, accepts any reagent; locked reagent optional
- Throughput
- Constant 200 tests/hour (mono or double reagent)
- Principle
- Colorimetry and turbidimetry
- Test methods
- 1 point end, 2 point end, fixed time, kinetics
- Calibration
- Linear and non-linear, multi-point up to 8 points
- Sample positions
- 40; micro cup, test tube or blood collection tube
- Sample volume
- 2–30 µL, in 0.1 µL steps
- Reagent positions
- 80 (40 for R1, 40 for R2), cooled 2–14 °C, 24 hours
- Reagent volume
- 20–300 µL, in 1 µL steps
- Reaction tray
- 44 UV plastic cuvettes, 37 ± 0.1 °C, 10 min reaction time
- Reaction volume
- 150–330 µL
- Optical system
- Halogen lamp; 340, 405, 450, 505, 546, 578, 630, 700 nm
- Absorbance range
- 0–4.0 Abs, resolution 0.0001 Abs
- Barcode reader
- Sample and reagent barcode, optional
- Interface
- TCP/IP network; Windows XP, 7, 8 or 10 software
- Power
- AC 110/220 V ± 10%, 50/60 Hz, 650 W
- Water use
- 8 L/hour maximum
- Dimensions
- 745 × 540 × 530 mm (L × W × H)
- Weight
- 45.4 kg
Which Chemistry Analyzer Do You Need?
MaxLYZER Smart and Smart Plus use a flow cell or cuvette. AutoMax 200 is fully automated.
| MaxLYZER Smart | MaxLYZER Smart Plus | AutoMax 200 | |
|---|---|---|---|
| Operation | Flow cell and cuvette mode | Flow cell and cuvette mode | Fully automated, random access |
| Throughput | – | – | Constant 200 tests/hour |
| Programmable tests | Up to 300 | Up to 300 | – |
| Coagulation | – | Optional | – |
| Wavelengths | 7 filters, 340–630 nm, 2 optional | 7 filters, 340–630 nm, 2 optional | 8 wavelengths, 340–700 nm |
| Absorbance range | 0–3.0000 Abs | 0–4.0000 Abs | 0–4.0 Abs |
| Results stored | Over 200,000 | Over 200,000 | – |
| CPU | ARM Cortex-A8, 720 MHz | ARM Cortex-A8, 800 MHz | Windows PC software |
| Dimensions | 400 × 300 × 160 mm | 450 × 300 × 220 mm | 745 × 540 × 530 mm |
– means the brochure does not state it.
Questions
Fully Automated Chemistry Analyzer FAQs
What can the AutoMax 200 test?
It runs colorimetric and turbidimetric chemistry tests by end point, fixed time and kinetic methods. Typical examples are glucose, cholesterol, creatinine and calcium, using a suitable reagent kit for each test.
What is the throughput of the AutoMax 200?
A constant 200 tests per hour, with single or double reagents. It has 40 sample positions and 80 reagent positions (40 for R1 and 40 for R2).
Is it an open system? Which reagents can I use?
Yes. The reagent system is open and accepts any reagent; a locked reagent mode is optional. You can run kits such as our calcium reagent, glucose reagent and creatinine reagent.
How much sample and reagent does each test use?
Sample volume is 2–30 µL and reagent volume is 20–300 µL. The total reaction volume can be as low as 150 µL, which keeps reagent cost per test down.
How quickly can you deliver fully automated chemistry analyzers, and do you ship outside India?
Orders are usually dispatched within 48 working hours. We deliver across India and also ship outside India. Bulk discounts are available: send the catalogue numbers and quantities on WhatsApp for a quote.
Used Together With
Get in Touch
Contact Us
Global Enquiry
Enquiry / Request Quote
For clinics, laboratories, and distributors seeking certified IVF and diagnostic products.
Direct Contact
WhatsApp · Tap to chat
Call · Tap to call
Email · Tap to email
Head Office
Paras Enterprise
117, Medicine Market, near Paldi Cross Road,
Opp. Shefali Centre, Paldi,
Ahmedabad, Gujarat – 380006
India
Mon–Sat · 9:30 AM – 7:30 PM IST