Glucose reagent, GOD-PAP method

Diagnostic Kits

Glucose Reagent Kit (LiquiMAX Glucose SLR)

A single liquid reagent for glucose in serum or plasma, using the GOD-PAP (Trinder) method, with end point and fixed time procedures.

  • GOD-PAP method
  • End point or fixed time
  • Linear to 500 mg/dl
  • Single liquid reagent
  • 100 mg/dl standard
  • Store at 2–8 °C

WhatsApp or call +91 98795 94445 or +91 96010 24737

Paras Enterprise · Since 2006 · 500+ clinics and hospitals · Dispatch within 48 working hours · Ships across India and abroad

What the Glucose Reagent Is Used For

Blood glucose is the main test for diagnosing and monitoring diabetes and for investigating low blood sugar. In this kit, glucose oxidase produces hydrogen peroxide, which reacts with phenol and 4-aminoantipyrine to form a red colour, read at 505 nm. The end point procedure takes 10 minutes at 37 °C, and a fixed time procedure is given for spectrophotometers and analyzers. A 100 mg/dl standard and a lipid clearing factor are included. The reagent is made by Avecon Healthcare in high-volume packs.

  • Fasting, post-meal and random blood glucose
  • Diagnosis and monitoring of diabetes
  • Investigating hypoglycaemia, including in newborns
  • High-volume routine testing in hospital and pathology labs

Glucose Reagent Specifications

Brand
Avecon Healthcare (LiquiMAX range)
Method
GOD-PAP (Trinder), enzymatic
Reaction
End point; fixed time option
Incubation
10 minutes at 37 °C or 15 minutes at room temperature
Wavelength
505 nm (490–550 nm)
Sample volume
10 µl
Reagent volume
1000 µl
Standard
100 mg/dl, included
Linearity
500 mg/dl (end point), 1000 mg/dl (fixed time)
Detection limit
5 mg/dl
Specimen
Serum or plasma; fluoride plasma preferred
Storage
2–8 °C, stable until expiry

Glucose Reagent Catalogue Numbers

Ref. No.Pack sizePresentation
AVGLU-500500 ml4 × 125 ml single liquid reagent
AVGLU-10001000 ml4 × 250 ml
AVGLU-50005000 ml5 × 1000 ml

Questions

Glucose Reagent FAQs

What does the glucose reagent measure?

Glucose in serum or plasma. It is used for fasting, post-meal and random glucose in the diagnosis and monitoring of diabetes and in the investigation of low blood sugar.

Which anticoagulant should I use?

Sodium fluoride is preferred because it stops glycolysis. Separate serum or plasma within 30 minutes, as glucose falls by about 7 mg/dl per hour at room temperature. Avoid more than 10 mg fluoride per ml of blood, as it can reduce colour development.

How long is the colour stable after the test?

The final colour is stable for 10 hours at room temperature. Samples above 500 mg/dl should be diluted with normal saline and the result multiplied by the dilution factor.

How should the reagent be stored?

Store at 2–8 °C. Stored properly, it is stable until the expiry date on the label.

How is the glucose reagent shipped, and how fast?

It is shipped in temperature-controlled packaging and usually dispatched within 48 working hours. We deliver across India and also ship outside India. Bulk discounts are available: ask on WhatsApp for a quote.

Get in Touch

Contact Us

Global Enquiry

Enquiry / Request Quote

For clinics, laboratories, and distributors seeking certified IVF and diagnostic products.

Direct Contact

Head Office

Paras Enterprise

117, Medicine Market, near Paldi Cross Road,
Opp. Shefali Centre, Paldi,
Ahmedabad, Gujarat – 380006
India

Mon–Sat · 9:30 AM – 7:30 PM IST