Homocysteine reagent kit with calibrators

Diagnostic Kits

Homocysteine Reagent Kit (LiquiMAX Homocysteine)

An enzymatic kit for homocysteine in serum or plasma on photometric systems, supplied with two liquid reagents and two calibrators.

  • Enzymatic method
  • 340 nm, fixed time
  • Linear to 50 µmol/L
  • 2 calibrators included
  • NIST SRM 1955 traceable
  • Store at 2–8 °C

WhatsApp or call +91 98795 94445 or +91 96010 24737

Paras Enterprise · Since 2006 · 500+ clinics and hospitals · Dispatch within 48 working hours · Ships across India and abroad

What the Homocysteine Reagent Is Used For

Raised homocysteine is linked to vascular damage and is also seen with B-vitamin deficiency, kidney failure and some genetic enzyme defects. This kit uses a series of enzyme reactions in which NADH is oxidised to NAD+, and the fall in absorbance at 340 nm is proportional to homocysteine. It runs as a 4-minute non-linear fixed time assay with multi-point calibration. The two calibrators are standardised to NIST SRM 1955, and results correlate with immunoassays. Made by Avecon Healthcare.

  • Measuring total homocysteine in serum or plasma
  • Cardiovascular risk assessment
  • Investigating vitamin B6, B12 or folate deficiency
  • Follow-up of kidney disease and genetic enzyme defects such as MTHFR

Homocysteine Reagent Specifications

Brand
Avecon Healthcare (LiquiMAX range)
Method
Enzymatic (NADH oxidation)
Reaction
Fixed time, non-linear, multi-point calibration
Reaction direction
Decreasing
Wavelength
340 nm
Temperature
37 °C
Timing
60 s delay + 180 s measuring
Sample volume
50 µl
Reagent volume
500 µl R1 + 50 µl R2
Calibrators
Two levels, lot-specific values on label
Linearity
50 µmol/L
Detection limit
2.5 µmol/L
Specimen
Serum, EDTA or heparin plasma, after 8 hours fasting
Storage
2–8 °C until expiry; 2 weeks once opened on the analyzer

Homocysteine Reagent Catalogue Numbers

Ref. No.Pack sizePresentation
AVHCY-2222 mlTwo liquid reagents with two-level calibrators
AVHCY-4444 mlTwo liquid reagents with two-level calibrators

Questions

Homocysteine Reagent FAQs

Why is homocysteine tested?

High homocysteine is linked to damage of the blood-vessel wall. It is also raised by B6, B12 or folate deficiency, kidney failure, some drugs and genetic defects such as MTHFR.

How should the patient sample be collected?

The patient should fast for at least 8 hours. Use serum or EDTA or heparin plasma. Keep the blood on ice if possible and centrifuge within an hour. Avoid haemolysed, turbid or very lipaemic samples.

Are calibrators included?

Yes. Two calibrators are supplied, standardised to NIST SRM 1955. Their values are lot-specific and printed on the label.

How long are the reagents stable?

Unopened, they are stable at 2–8 °C until the expiry date. Once opened and kept on an automated analyzer, they can be used for 2 weeks. Patient samples are stable for 7 days at 2–8 °C.

How is the homocysteine reagent shipped, and how fast?

It is shipped in temperature-controlled packaging and usually dispatched within 48 working hours. We deliver across India and also ship outside India. Bulk discounts are available: ask on WhatsApp for a quote.

Get in Touch

Contact Us

Global Enquiry

Enquiry / Request Quote

For clinics, laboratories, and distributors seeking certified IVF and diagnostic products.

Direct Contact

Head Office

Paras Enterprise

117, Medicine Market, near Paldi Cross Road,
Opp. Shefali Centre, Paldi,
Ahmedabad, Gujarat – 380006
India

Mon–Sat · 9:30 AM – 7:30 PM IST