Diagnostic Kits
Ammonia Reagent Kit (LiquiMAX Ammonia)
A liquid, ready-to-use enzymatic reagent for measuring ammonia in plasma, read as a UV fixed-rate reaction at 340 nm. An aqueous calibrator is included.
- Enzymatic UV method
- Fixed rate, 340 nm
- Linear to 1700 µg/dl
- Calibrator included
- Plasma only
- Store at 2–8 °C
WhatsApp or call +91 98795 94445 or +91 96010 24737
Paras Enterprise · Since 2006 · 500+ clinics and hospitals · Dispatch within 48 working hours · Ships across India and abroad
What the Ammonia Reagent Is Used For
Blood ammonia rises when the liver cannot clear it, as in severe liver failure, and in inherited urea-cycle disorders. This kit measures ammonia directly in plasma, with no separation step. Ammonia combines with α-ketoglutarate and NADH in a glutamate dehydrogenase reaction, and the fall in absorbance at 340 nm is proportional to the ammonia level. The liquid mono reagent comes with an aqueous calibrator. It is made by Avecon Healthcare and suits semi-automated systems.
- Measuring plasma ammonia in suspected liver failure
- Investigating suspected urea-cycle and other inherited metabolic disorders
- Monitoring patients with raised ammonia
Ammonia Reagent Specifications
- Brand
- Avecon Healthcare (LiquiMAX range)
- Method
- Direct enzymatic (GLDH), UV fixed rate
- Reaction direction
- Decreasing
- Wavelength
- 340 nm
- Temperature
- 37 °C
- Timing
- 60 s delay + 120 s measuring
- Sample volume
- 25 µl
- Reagent volume
- 500 µl
- Calibrator
- 200 µg/dl, included
- Linearity
- 1700 µg/dl
- Detection limit
- 13 µg/dl
- Specimen
- EDTA or heparin plasma; not serum
- Storage
- 2–8 °C, stable until expiry
Ammonia Reagent Catalogue Numbers
| Ref. No. | Pack size | Presentation |
|---|---|---|
| AVAMM-10 | 10 ml | Liquid mono reagent with calibrator |
| AVAMM-25 | 25 ml | Liquid mono reagent with calibrator |
Questions
Ammonia Reagent FAQs
What is the ammonia reagent kit used for?
It measures ammonia in plasma. Raised ammonia is seen in severe liver failure and in inherited urea-cycle and related metabolic disorders.
Can I use serum?
No. Use EDTA or heparin plasma only. Red cells hold about three times more ammonia than plasma, so avoid haemolysis. Samples are stable for 3 hours at 2–4 °C or 24 hours at -20 °C.
What if the result is above the linear range?
The assay is linear to 1700 µg/dl. Dilute higher samples with ammonia-free water, re-run them and multiply the result by the dilution factor.
How should the reagent be stored?
Keep it capped at 2–8 °C. Stored this way, it is stable until the expiry date on the label.
How is the ammonia reagent shipped, and how fast?
It is shipped in temperature-controlled packaging and usually dispatched within 48 working hours. We deliver across India and also ship outside India. Bulk discounts are available: ask on WhatsApp for a quote.
Used Together With
Get in Touch
Contact Us
Global Enquiry
Enquiry / Request Quote
For clinics, laboratories, and distributors seeking certified IVF and diagnostic products.
Direct Contact
WhatsApp · Tap to chat
Call · Tap to call
Email · Tap to email
Head Office
Paras Enterprise
117, Medicine Market, near Paldi Cross Road,
Opp. Shefali Centre, Paldi,
Ahmedabad, Gujarat – 380006
India
Mon–Sat · 9:30 AM – 7:30 PM IST