Blastomere Biopsy Micropipette: Embryo Biopsy Techniques, Tip Types & Specifications

Published on 1 Jun 2026

Blastomere biopsy micropipette for PGT, supplied across India by Paras Enterprise

A blastomere biopsy micropipette is a fine glass pipette used to remove one cell (a blastomere) from a Day 3 cleavage-stage embryo for preimplantation genetic testing (PGT). Paras Enterprise supplies blastomere biopsy micropipettes to IVF labs across India: flat tip (30 or 35 µm) or bevelled tip (30 µm), straight or angled from 15° to 45°, MEA tested and gamma sterilised, 10 per box.

View the blastomere biopsy micropipette · Request a quote: WhatsApp or call +91 98795 94445 · Send an enquiry

Blastomere biopsy micropipette

What is blastomere biopsy?

Blastomere biopsy is the removal of a single cell from an embryo at the cleavage stage, usually on Day 3 when the embryo has around six to eight cells. The embryologist first makes an opening in the zona pellucida (the embryo's outer shell), then uses the biopsy micropipette to gently draw one cell out while a holding micropipette keeps the embryo steady. The removed cell is sent for genetic testing.

Embryo biopsy techniques: polar body vs blastomere vs trophectoderm

There are three embryo biopsy techniques, done at different stages. Each needs its own micropipette, so they are not interchangeable.

Embryo biopsy techniques compared
Polar body biopsyBlastomere biopsyTrophectoderm biopsy
StageOocyte or zygoteDay 3 cleavage-stage embryoDay 5–6 blastocyst
What is removedPolar bodyOne blastomere (cell)A few trophectoderm cells
Our micropipettePolar body biopsyBlastomere biopsyTrophectoderm biopsy, bevelled or flat
Inner diameter15 µm30 or 35 µm (flat), 30 µm (bevelled)15, 20 or 25 µm
Taper length700 µm700 µm900 µm
ConfigurationsStraight, 15°–45°Straight, 15°–45°Straight, 15°–35°

Many IVF programmes now biopsy at the blastocyst stage (trophectoderm biopsy), and ESHRE's PGT Consortium good practice recommendations cover all three approaches. Your lab director chooses the technique; the micropipette must match it.

Embryo biopsy micropipettes compared: polar body, blastomere and trophectoderm

Flat tip vs bevelled tip: which should you choose?

Both tip types are used for blastomere biopsy. The difference is the shape of the opening.

Flat tipBevelled tip
OpeningStraight, square-cut endAngled, slanted end
Inner diameter (ours)30 µm or 35 µm30 µm
Typical useDrawing a cell out through an opening already made in the zonaWhere the embryologist prefers an angled opening to pass through the zona opening

Choose the tip type and inner diameter your lab's protocol specifies. If you are changing tip type, trial a box first before switching your whole stock.

Straight vs angled blastomere biopsy micropipettes

Choose the angle that matches how your pipette holder is mounted, so the tip lies flat in the dish. We supply blastomere biopsy micropipettes straight or angled from 15° to 45°. Use the same angle as your holding micropipette so both work on the same plane.

Blastomere biopsy micropipette specifications

SpecificationValue
Tip typesFlat (30 µm / 35 µm), bevelled (30 µm)
ConfigurationsStraight, or angled from 15° to 45°
Taper length700 µm
Measurement tolerance±5%, every pipette individually inspected
MaterialBorosilicate glass, heat-polished base
TestingMEA tested
SterilisationGamma
Pack size10 pieces per box
Blastomere biopsy micropipette specifications
Key features of our blastomere biopsy micropipettes

Questions to ask before buying biopsy micropipettes

  1. Which biopsy technique does your lab use? Polar body, blastomere or trophectoderm, because each needs a different pipette.
  2. Tip type and inner diameter: flat 30 or 35 µm, or bevelled 30 µm, as your protocol specifies.
  3. Angle: matches your pipette holder and your holding micropipette.
  4. MEA test report: see our certifications page.
  5. Sterility and expiry: gamma sterilised, with the expiry date on the pack.
  6. Lot number on every box: for your PGT records.
  7. Brochure: download the blastomere biopsy micropipette brochure (PDF).

Why order biopsy micropipettes from Paras Enterprise?

  • Every biopsy type in one place: polar body, blastomere and trophectoderm micropipettes, plus matching holding micropipettes.
  • Authorised distributor with MEA reports and lot traceability.
  • India-wide supply to IVF labs across Gujarat, Maharashtra, Delhi NCR, Rajasthan and Karnataka.
  • Technical help choosing tip type, inner diameter and angle.

Request a quote for biopsy micropipettes

Tell us your biopsy technique, tip type, angle and monthly volume, and we will reply with a quotation and the product documents.

Request a quote for biopsy micropipettes from Paras Enterprise
  • WhatsApp / Call: +91 98795 94445 · +91 96010 24737
  • Email: admin@parasenterpriseglobal.com
  • Office: 117, Medicine Market, near Paldi Cross Road, opp. Shefali Centre, Paldi, Ahmedabad, Gujarat 380006
  • Hours: Monday to Saturday, 9:30 AM to 7:30 PM IST

View the blastomere biopsy micropipette or send an enquiry.

FAQ

Frequently Asked Questions

What is a blastomere biopsy micropipette used for?

It is used to remove one cell (a blastomere) from a Day 3 cleavage-stage embryo for preimplantation genetic testing (PGT), while a holding micropipette keeps the embryo steady.

What is the difference between blastomere biopsy and trophectoderm biopsy?

Blastomere biopsy removes one cell from a Day 3 embryo, while trophectoderm biopsy removes a few cells from the outer layer of a Day 5–6 blastocyst. They use different micropipettes and are not interchangeable.

What tip sizes are available for blastomere biopsy micropipettes?

We supply flat tips with a 30 µm or 35 µm inner diameter and bevelled tips with a 30 µm inner diameter, straight or angled from 15° to 45°.

Should I choose a flat or bevelled biopsy micropipette?

Choose the tip your lab's protocol specifies. A flat tip has a square-cut opening and a bevelled tip has an angled opening; trial a box before switching types.

Are your biopsy micropipettes MEA tested and sterile?

Yes. They are MEA tested, gamma sterilised and made from borosilicate glass to a ±5% tolerance, with every pipette individually inspected. Each box contains 10 pipettes.

Do you supply polar body and trophectoderm biopsy micropipettes too?

Yes. We supply polar body biopsy micropipettes (15 µm) and trophectoderm biopsy micropipettes in flat and bevelled tips (15, 20 or 25 µm), across India.

Contact & Enquiry

Direct Contact

Head Office

Paras Enterprise

117, Medicine Market, near Paldi Cross Road,
Opp. Shefali Centre, Paldi,
Ahmedabad, Gujarat - 380006
India

Mon-Sat · 9:30 AM - 7:30 PM IST

Global Enquiry

Request Quote

Share your requirement and our team will respond with a suitable quotation and compliance details.